What does a refined salt dryer have to achieve, and why does it cake anyway? A refined or vacuum salt line usually dries centrifuged salt from a few per cent moisture to well below 0.5%, then cools it before packing. The limits that matter in India are 0.5% maximum moisture for refined iodised salt under IS 7224, 1.5% for double fortified salt (DFS) under FSSAI, and 6% for common edible salt. Most caking complaints come from salt that was packed warm, from fines, or from moisture picked up after the dryer, not from the dryer missing its outlet moisture. A fluid bed dryer with an integrated cooling section is the usual answer for refined grades. This guide is for salt refinery managers and project engineers.
Moisture figures are percentages by mass on a wet basis, as the standards express them.
Why is salt drying in the news?
Double fortified salt (iodine plus iron) is being discussed again as an anaemia measure. Tamil Nadu pushed for supplying DFS through ration shops (Times of India, 10 February 2026). An op-ed in The Hindu (27 October 2026) argued for wider use of DFS. Public health experts quoted by the Times of India (15 November 2026) cautioned against scaling up without stronger evidence. Policy is still being argued. For salt producers, though, DFS means a tighter moisture and purity specification than ordinary iodised salt, and that falls on the drying and cooling section.
Which moisture limits apply?
| Product | Moisture limit | Source | Other limits that affect drying |
|---|---|---|---|
| Edible common salt (incl. iodised) | Not more than 6.0% of the undried sample | FSSAI Reg. 2.9.30 | NaCl ≥ 96.0% (dry basis); ≥ 97.0% where anticaking agent is added |
| Iron fortified iodised salt (DFS) | Not more than 1.5% | FSSAI Reg. 2.9.30 (5) | NaCl ≥ 99.0% (non-encapsulated premix) or ≥ 98.0% (encapsulated), dry basis |
| Refined or vacuum evaporated iodised salt | 0.5% maximum | IS 7224:2006 | NaCl ≥ 98.5% (dry basis); refined grade ≥ 95% passing 1 mm and not more than 10% passing 150 µm |
| Iodised salt (non-refined) | 6.0% maximum | IS 7224:2006 | ≥ 95% passing 4.00 mm |
Sources: the FSSAI salt, spices and condiments chapter (compendium version dated 1 September 2023) and IS 7224:2006. Check the current editions before you write a specification. This article does not give a compliance opinion.
The particle size clause matters as much as moisture. A refined salt with no more than 10% passing 150 µm cannot be dried in a way that grinds crystals or carries excess fines into the product. Fluid bed air velocity, vibration and dust collection all affect this.
Worked example: the heat load is not just evaporation
Assumed basis: 10 t/h of refined salt product at 0.2% moisture, from centrifuge cake at 3.0%. These are illustrative figures; use your own centrifuge data.
| Item | Calculation | Result |
|---|---|---|
| Dry salt | 10,000 × 0.998 | 9,980 kg/h |
| Wet feed at 3.0% | 9,980 ÷ 0.97 | 10,289 kg/h |
| Water evaporated | 10,289 − 10,000 | 289 kg/h |
| Heat to evaporate (≈ 2,500 kJ/kg assumed) | 289 × 2,500 | ≈ 0.72 GJ/h (≈ 200 kW) |
| Heat to warm salt from 30°C to 100°C (cp ≈ 0.88 kJ/kg·K) | 10,000 × 0.88 × 70 | ≈ 0.62 GJ/h (≈ 171 kW) |
| Heat to remove in cooling, 100°C to 40°C | 10,000 × 0.88 × 60 | ≈ 0.53 GJ/h (≈ 147 kW) |
Warming the salt itself takes almost as much heat as evaporating the water. This is the opposite of most food or chemical drying. Three practical points follow:
- Do not oversize the heater on water alone. Size it on evaporation plus salt sensible heat plus losses. Quotations based only on “kg/h water evaporated” understate the load.
- Do not dry hotter than needed. Each extra 10 K of product temperature adds about 0.09 GJ/h of heating here, and the cooler has to remove it again.
- The cooling section matters. Salt packed warm into bags or silos releases moisture that condenses as it cools, which bridges crystals into lumps. Cool to near ambient with air dry enough not to add moisture back. In coastal monsoon conditions this may mean dehumidified or chilled air.
The figures ignore radiation losses and exhaust air humidity, and the heat demand is thermal energy, separate from fan and vibration motor power. Use them for trends, not for setting a specific dryer.
Fluid bed, rotary or flash: which fits?
| Dryer | Strength for salt | Limitation |
|---|---|---|
| Fluid bed / vibro fluid bed with cooling zone | Uniform drying of free-flowing crystals; drying and cooling in one unit; good control of fines carry-over | Needs a reasonably narrow size range; sticky or very wet feed must be pre-dewatered |
| Rotary dryer | Tolerates coarse, lumpy or wetter bulk salt; high throughput | More attrition (fines); a separate cooler is usually needed |
| Flash dryer | Very short contact; suits fine salt powders | Product separation from air is the whole process; fines and dust load are high |
GTI’s salt drying systems page lists all three and describes fluidised bed dryers as the most widely used for salt. GTI’s salt processing machinery page also covers iodisation and fortification units for DFS, screening, blending and packing, with SS304/SS316 construction. See also the vibratory fluid bed dryer page.
Where does DFS change the design?
- Lower moisture and higher purity. DFS allows 1.5% moisture against 6% for common salt, and needs at least 98–99% NaCl on a dry basis. The feed salt usually has to be refined (washed, dewatered and dried) before fortification.
- Order of operations. The iron premix is normally blended into dry, cooled salt, so it is not exposed to dryer heat. Iodisation spray adds moisture, so decide whether iodate goes on before the dryer or onto dried salt with a small finishing step. Your premix supplier’s handling conditions set this.
- Blending and segregation. Premix particles must stay evenly spread through packing. Particle size of the dried salt affects segregation, so screening after the cooler is part of the fortification design.
- Corrosion. Salt dust and humid air corrode carbon steel quickly. Specify materials, sealing and wash-down access for contact parts and ducting.
Common mistakes
- Setting dryer outlet moisture far below the limit to “stop caking” when the real cause is warm packing or humid storage.
- Running high air velocity to push capacity, which carries saleable crystals to the bag filter and breaks crystals into fines.
- Ignoring centrifuge performance. Every 1% extra cake moisture adds about 100 kg/h of water in this example, roughly a third more evaporation.
- Measuring moisture once a shift on a hand-drawn sample and not trending it against feed rate and air temperature.
Frequently asked questions
Does solar (pan) salt need a dryer?
Common salt may contain up to 6% moisture under FSSAI, so crushed and iodised solar salt is often sold without thermal drying. Refined, free-flowing and DFS grades need drying to meet their tighter limits.
Is an anticaking agent a substitute for drying?
No. Permitted anticaking agents help flow, but they do not remove moisture. FSSAI also limits water-insoluble matter where anticaking agent is added (not more than 2.2%).
What capacity range can be supplied?
Salt dryers are designed for each case. Send your required tonnes per hour and moisture data for a specific proposal.
About Genex Tech Industries LLP (GTI Group)
Genex Tech Industries LLP (GTI Group) designs and manufactures industrial dryers, including fluid bed, rotary and flash dryers for salt described on its salt drying page. On this site, see our drying machines, screening machines and mixer machines pages, and our guide on choosing an industrial dryer. The head office is at 10C Middleton Row, Kolkata 700071, India.
Sources and authorship
- FSSAI, Food Safety and Standards (Food Products Standards and Food Additives) Regulations, 2011, Regulation 2.9.30, compendium version 1 dated 1 September 2023.
- Bureau of Indian Standards, IS 7224:2006, Iodized salt, vacuum evaporated iodized salt and refined iodized salt.
- Times of India, “TN bats for double fortified salt to tackle anaemia crisis”, 10 February 2026.
- The Hindu, “A ready solution to tackle anaemia” (op-ed), 27 October 2026.
- Times of India, “Launching new anti-anaemia strategy without enough evidence could waste public funds, warn experts”, 15 November 2026.
- Published salt drying and salt processing pages of Genex Tech Industries LLP (GTI Group).
The heat balance is an illustrative calculation from stated assumptions, not a measurement from any plant. This article was prepared by the editorial team of Genex Tech Industries LLP (GTI Group) with AI editorial assistance. It has not been reviewed by a named engineer, and no individual is cited as having approved the technical content.
Next step
Planning a refined salt or DFS drying line, or fighting caking? Email mktg@gtidryers.com or use the contact page. Send the salt type, centrifuge cake moisture, target moisture and particle size, required t/h, fortification plan, available fuel or steam, ambient conditions and the installation location.